Electrically Operated Explosion Proof/Dust Ignition Proof Vacuum Cleaner systems
|
|||||
European customers:Tiger-Vac offers a complete line of ATEX compliant Explosion/Dust ignition proof vacuum cleaners. Please click here to access our European website (this link will open a new window).
|
|||||
|
|||||
| Certified for use in NFPA (NEC) 70-500: Class I - Groups D T3C Class II - Groups F & G |
- CSA certified explosion proof/dust ignition proof vacuum cleaner .
- ULPA or HEPA filtration available.
- Cleanroom compatible.
- Continuous duty 3-phase motor.
- Stainless steel AISI 304/316 construction.
- For dry recovery only
- Brochure
- Certificate.
CD-2600 EX CR PHARMA (ARP/MFS/MRP)
Dry recovery
| Certified for use in NFPA (NEC) 70-500: Class I - Groups D T3C Class II - Groups F & G |
- Static dissipative and conductive.
- HEPA/ULPA filtration.
- Continuous duty single and 3-phase motor.
- Heavy duty powder coated construction. Also available in Stainless Steel AISI 304 construction (recovery tank or complete unit).
- Available with Manual Filter Shaker (MFS), Manual Reverse Purge (MRP), Automatic Reverse Purge (ARP).
- For dry recovery only.
- Brochures:
- CD-2600 EX CR ARP
- CD-2600 EX CR MFS
- CD-2600 EX CR MRP

CD-3 EX PHARMA Series
Wet and dry recovery
| Certified for use in NFPA (NEC) 70-500: Class I - Group D and Class II - Groups F & G Class II Group E metal dust motor available - Optional |
- CSA certified explosion proof/dust ignition proof vacuum cleaner
- HEPA filtration (ULPA available).
- Cleanroom compatible.
- Continuous duty 3-phase motor.
- Available with Manual Filter Shaker (MFS), Manual Reverse Purge (MRP), Automatic Reverse Purge (ARP) or Liquid bath immersion (for dry recovery only).
- Available with Middle Ring with Activated Carbon (MRAC).
- All Stainless Steel AISI 304 construction (AISI 316 electropolished available).
- Detachable recovery tank (DT).
- MFS/MRP/ARP: Brochure
- Wet and dry/MRAC :Brochure
- Liquid bath Immersion: Contact
- Certificate.

CD-2 EX PHARMA Series
Wet and Dry recovery
| Certified for use in NFPA (NEC) 70-500: Class I - Groups D T3C Class II - Groups F & G Class II Group E - metal dust motor available - Optional |
- CSA certified explosion proof/dust ignition proof vacuum cleaner
- ULPA filtration.
- Cleanroom compatible.
- Continuous duty 3-phase motor.
- Middle Ring with Activated Carbon (MRAC) for wet and dry recovery
- Stainless steel AISI 304/316 construction. Autoclavable electropolished recovery tank and middle ring.
- For wet and dry recovery.
- Contact us for more information.
- Certificate.

CD-IT EX (CFE) HY-C
Wet and Dry recovery
| Certified for use in NFPA (NEC) 70-500: Class I - Group D and Class II - Groups E, F & G (Group E - 3 phase motor available) |
- CSA certified explosion proof/dust ignition proof vacuum cleaner
- Coalescing filter element
- For the recovery and neutralization of conductive and explosive dust into a liquid bath
- Continuous duty single or 3-phase motor
- Hydraulic cart for easy emptying
- Stainless steel AISI 304 Interceptor tank
- For wet and dry recovery only.
- Brochure

CD-4 EX, CD-5 EX,
CD-7 EX CD-10 EX PHARMA
Dry recovery
| Certified for use in NFPA (NEC) 70-500: Class I - Group D and Class II - Groups F & G |
- CSA certified explosion proof/dust ignition proof vacuum cleaner
- HEPA filtration (ULPA available).
- Cleanroom compatible.
- Continuous duty 3-phase motor.
- Manual or fully automatic filtration cleaning systems.
- All Stainless Steel AISI 304 construction (AISI 316 electropolished available).
- For dry recovery (liquids can be recovered into a separate tank).
- Detachable recovery tank (DT).
- CD-4/5 EX MFS/MRP: Brochure
- CD-4/5/7/10 EX AFS/APS/RPS: Brochure
- Certificate.
.jpg)
EXP1-35L RE HEPA
Dry recovery
| Certified for use in NFPA (NEC) 70-500: Class I - Group D and Class II - Groups E, F & G |
- CSA certified explosion proof/dust ignition proof vacuum cleaner
- HEPA filter.
- Single phase motor.
- Stainless steel AISI 304 construction.
- Available with Manual Filter Shaker (MFS) or Manual Reverse Purge (MRP)
- Detachable recovery tank (DT).
- For dry recovery only.
- Brochure (MFS)
- Brochure (MRP)
- Certificate.

EXP1-20L DT
Dry recovery
| Certified for use in NFPA (NEC) 70-500: Class I - Group D and Class II - Groups E, F & G |
- CSA certified explosion proof/dust ignition proof vacuum cleaner
- HEPA filtration, ULPA filtration optionnal.
- Single phase motor.
- Manual Filter Shaker (MFS).
- Stainless steel AISI 304 construction.
- For dry recovery only.
- Detachable recovery tank (DT).
- Brochure
- Certificate.
Alternate version:
- Static dissipative and grounded: HLMT-20 DT Tech. information and accessories

EXP1-10 to 55 RE Series
Wet and dry recovery
| Certified for use in NFPA (NEC) 70-500: Class I - Group D and Class II - Groups E, F & G |
- CSA certified explosion proof/dust ignition proof vacuum cleaner
- HEPA/ULPA Filtration available
- Middle Ring with Activated Carbon (MRAC) available for wet and dry recovery (EXP1-10 only).
- Single phase motor.
- Available with an Interceptor unit on a single cart (EXP1-25 only)
- All stainless steel AISI 304 construction (except tilt cart).
- For wet and dry recovery.
- Based either on a 4 wheel dolly or on a 4 wheel tilting cart to allow for easy emptying of recovered materials.
- Brochure
- With interceptor unit: Brochure
- Certificate.
Alternate version:
- Static dissipative and grounded models: BLSD-20 (DT) MFS Brochure and HLMT-20 (DT)

EXP1-40L RE HEPA
Dry recovery
| Certified for use in NFPA (NEC) 70-500: Class I - Group D and Class II - Groups E, F & G |
- CSA certified explosion proof/dust ignition proof vacuum cleaner
- HEPA filter.
- Single phase motor.
- Stainless steel AISI 304 construction.
- Detachable recovery tank (DT).
- For dry recovery only.
- Brochure
- Certificate.

Continuous Duty Power Unit (CDPU PHARMA)
| Certified for use in NFPA (NEC) 70-500: Class I - Group D and Class II - Groups E, F & G |
- CSA certified explosion proof/dust ignition proof vacuum cleaner power unit
- HEPA/ULPA Filtration available
- Available with Manual Filter Shaker (MFS) or Manual Reverse Purge (MRP)
- Continuous duty three phase motor.
- Brochure
- Certificate.
Pneumatically (air) Operated Explosion proof Vacuum Cleaner Systems
Fuel and solvent recovery Vacuum Cleaner Systems
Static Dissipating/grounded Vacuum Cleaner Systems
Shooting range maintenance Vacuum Cleaner Systems
How to choose an Explosion proof Vacuum Cleaner Systems
Information on electric and pneumatic power sources
Tools and accessories for explosion proof/dust ignition proof vacuum cleaner systems



What to do about combustible dusts?-ULPA.jpg)