E-mail Print PDF
ex-mat-logo

Tiger-Vac, as the manufacturer, GUARANTEES, that these units of category 1 & 2, can be used to safely recover combustible /conductive dusts and/or flammable liquids.

The ATEX marking certifies only, by it's Ingress of Protection (IP),  the capacity of the vacuum cleaner to be in the presence of combustible /conductive dusts and/or flammable liquids but does not certify the capacity of the vacuum cleaner to recover them.

ATEX Definitions & Applications

Explosion Proof/Dust Ignition Proof Continuous Duty Vacuum Cleaner Systems

ATEX Category 2 Explosion Proof Vacuum Cleaner Systems for ATEX Zone 1 (Gas) and ATEX Zone 21 (Dust)


CD-EX Series

CD-1500 EX CR *Pharma - Dry Recovery
ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X - T135oC
LCIE 03 ATEX 6295
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822. Or ULPA Filter - Optional with an efficiency of 99.999% on 0.12 micron. Tested: IEST RP-CC001.3. Filtration efficiency of 99.9995% on 0.18 micron. Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • Designed for general cleanup
  • Continuous duty single or 3-phase explosion proof/dust ignition proof motor
  • Equipped with disposable filter bags - 2 gallons (8 liters) recovery capacity
  • Available in a fixed or mobile unit
  • For dry recovery only
  • All stainless steel AISI 304 construction
  • Unit is compact with a small footprint
  • Recovery tank capacity of 5 gallons (19 liters) in recovery tank
  • Equipped with 4 wheels
All stainless steel AISI 304 construction.  Less than 10 Ohms of resistivity.  This unit is available with an optional true HEPA (H14) / ULPA (U15) Filter located downstream outside of the motor housing.  This unit is cleanroom compatible and can be used in the pharmaceutical industry.  This unit can be used for general maintenance in hazardous locations.  Equipped with a disposable filter bag for the easy and safe disposal of recovered materials.  All of our HEPA/ULPA vacuum cleaners are DOP Leak Tested before leaving our facility.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.99% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 micron or larger.

North-America: Each HEPA Filter has a minimum filtration efficiency of 99.99% on 0.3 micron.  Tested as per IES-RP-CC001.3.

Europe: Each HEPA Filter has a minimum filtration efficiency of 99.995% on 0.3 micron, rated H14 as per EN 1822 by MPPS method.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron.  Tested as per IES-RP-CC001.3.

Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

Name Description Download
CD-1500 EX CR Brochure (Metric) Technical data for CD-1500 EX CR in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-1500 EX CR Brochure (Imperial) Technical data for CD-1500 EX CR in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download
CD-1501 EX CR *Pharma - Dry Recovery
ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X - T135oC
LCIE 03 ATEX 6295
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822. Or ULPA Filter - Optional with an efficiency of 99.999% on 0.12 micron. Tested: IEST RP-CC001.3. Filtration efficiency of 99.9995% on 0.18 micron. Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • Designed with a powerful suction for the recovery of tablets
  • Continuous duty single or 3-phase explosion proof/dust ignition proof motor
  • Available with optional disposable filter bags - 2 gallons (8 liters) recovery capacity
  • Available in a fixed or mobile unit
  • For dry recovery only
  • All stainless steel AISI 304 construction
  • Unit is compact with a small footprint
  • Recovery tank capacity of 7.5 gallons (28.5 liters) in recovery tank
  • Equipped with 4 wheels
All stainless steel AISI 304 construction.  Less than 10 Ohms of resistivity.  This unit is available with a true HEPA (H14) / ULPA (U15) Filter located downstream outside of the motor housing.  This unit is cleanroom compatible and can be used in the pharmaceutical industry.  This unit has been designed with a powerful suction for the recovery of tablets.  All of our HEPA/ULPA vacuum cleaner are DOP Leak Tested before leaving our facility

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.99% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 micron or larger.

North-America: Each HEPA Filter has a minimum filtration efficiency of 99.99% on 0.3 micron.  Tested as per IES-RP-CC001.3.

Europe: Each HEPA Filter has a minimum filtration efficiency of 99.995% on 0.3 micron, rated H14 as per EN 1822 by MPPS method.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron.  Tested as per IES-RP-CC001.3.

Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

Name Description Download
CD-1501 EX CR Brochure (Metric) Technical data for CD-1501 EX CR in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-1501 EX CR Brochure (Imperial) Technical data for CD-1501 EX CR in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download
CD-2600 EX (ARP) *Pharma - Dry Recovery

GUARANTEED to be capable of safely recovering
combustible/conductive dusts &/or flammable liquids.

ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X - T135oC
LCIE 03 ATEX 6295
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822. Or ULPA Filter - Optional with an efficiency of 99.999% on 0.12 micron. Tested: IEST RP-CC001.3. Filtration efficiency of 99.9995% on 0.18 micron. Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.
  • *Cleanroom compatible. Can be used in the pharmaceutical industry
  • Designed for general cleanup in hazardous locations
  • Continuous duty single or 3-phase explosion proof/dust ignition proof motor
  • Available with Automatic Reverse Purge (ARP)
  • Available in a fixed or mobile unit
  • All stainless steel AISI 304/316 construction
  • For dry recovery only (liquids can be recovered into a separate tank)
  • Detachable recovery tank (DT) for easy disposal of recovered materials. Recovery capacity of 9.5 gallons (36 liters)
  • Unit is compact with small footprint
  • Equipped with 4 wheels
All stainless steel construction.  Less than 10 Ohms of resistivity.   This unit is available with an optional true HEPA (H14) / ULPA (U15) Filter located downstream outside of the motor housing.  This unit is cleanroom compatible and can be used in the pharmaceutical industry.  Available with Automatic Reverse Purge (ARP).  The vacuum cleaner is mounted on 4 wheels with locks for easy manoeuverability and facilitates access to processing equipment when used as a mobile unit.  All of our ULPA vacuum cleaners are DOP Leak Tested before leaving our facility.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.99% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 micron or larger.

North-America: Each HEPA Filter has a minimum filtration efficiency of 99.99% on 0.3 micron.  Tested as per IES-RP-CC001.3.

Europe: Each HEPA Filter has a minimum filtration efficiency of 99.995% on 0.3 micron, rated H14 as per EN 1822 by MPPS method.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron.  Tested as per IES-RP-CC001.3.

Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.

ARP - Automatic Reverse Purge

ARP

The Automatic Reverse Purge System requires a small 2 HP compressor on a 1/4" air line hose @ 5 bar (80 psi), 3.78 l/s (8 cfm) to feed the system. This system is ideal when the vacuum cleaner will be attached to a processing system and the operator does not have the time to continually perform a manual purge. A flap has been installed inside of the suction port and will close automatically when the vacuum cleaner is turned off, thus eliminating the risk that any powders or debris will escape from the unit when operating the ARP without any suction power.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

DT - Detachable Recovery Tank

detachable-tankMany of our vacuum cleaners come equipped with a detachable tank for the easy disposal of recovered materials. Our detachable tanks range in size from 20 to 160 liters (5.28 gal to 42.25 gal) and are available in stainless steel or powder coated, with or without wheels for maneuverability.

Name Description Download
CD-2600 EX (ARP) Brochure (Metric) Technical data for CD-2600 EX (ARP) in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-2600 EX (ARP) Brochure (Imperial) Technical data for CD-2600 EX (ARP) in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download
CD-2600 EX (MRP) *Pharma - Dry Recovery

GUARANTEED to be capable of safely recovering
combustible/conductive dusts &/or flammable liquids.

ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X - T135oC
LCIE 03 ATEX 6295
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822. Or ULPA Filter - Optional with an efficiency of 99.999% on 0.12 micron. Tested: IEST RP-CC001.3. Filtration efficiency of 99.9995% on 0.18 micron. Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.
  • *Cleanroom compatible. Can be used in the pharmaceutical industry
  • Designed for general cleanup in hazardous locations
  • Continuous duty single or 3-phase explosion proof/dust ignition proof motor
  • Available withManual Reverse Purge (MRP)
  • Available in a fixed or mobile unit
  • All stainless steel AISI 304/316 construction
  • For dry recovery only (liquids can be recovered into a separate tank)
  • Detachable recovery tank (DT) for easy disposal of recovered materials. Recovery capacity of9.5 gallons (36 liters)
  • Unit is compact with small footprint
  • Equipped with 4 wheels
All stainless steel construction.  Less than 10 Ohms of resistivity.  This unit is available with an optional true HEPA (H14) / ULPA (U15) Filter located downstream outside of the motor housing.  This unit is cleanroom compatible and can be used in the pharmaceutical industry.  Available in Manual Reverse Purge (MRP).  The vacuum cleaner is mounted on 4 wheels with locks for easy manoeuverability and facilitates access to processing equipment when used as a mobile unit.  All of our ULPA vacuum cleaners are DOP Leak Tested before leaving our facility.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.99% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 micron or larger.

North-America: Each HEPA Filter has a minimum filtration efficiency of 99.99% on 0.3 micron.  Tested as per IES-RP-CC001.3.

Europe: Each HEPA Filter has a minimum filtration efficiency of 99.995% on 0.3 micron, rated H14 as per EN 1822 by MPPS method.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron.  Tested as per IES-RP-CC001.3.

Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.

MRP - Manual Reverse Purge System

MRP The Manual Reverse Purge (MRP) System allows the operator to not have to open the vacuum cleaner in order to clean the Cartridge. By opening the Reverse Purge Atmospheric Pressure Release Valve the Cartridge is automatically purged of dusts. This Purging System reduces maintenance down time.

The Manual Reverse Purge (MRP) works by :

1 - Closing the slider on the opening to block the suction intake orifice for approximately 5 seconds while the vacuum is running.

2 - Then quickly open Purge Valve. Air is now flowing via the valve through to the filter.

Keep Purge Valve open for 1-2 seconds then close (repeat above steps 2 or 3 times).

Reverse Purge System will cause dust to fall off of the filter.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

DT - Detachable Recovery Tank

detachable-tankMany of our vacuum cleaners come equipped with a detachable tank for the easy disposal of recovered materials. Our detachable tanks range in size from 20 to 160 liters (5.28 gal to 42.25 gal) and are available in stainless steel or powder coated, with or without wheels for maneuverability.

Name Description Download
CD-2600 EX (MRP) Brochure (Metric) Technical data for CD-2600 EX (MRP) in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-2600 EX (MRP) Brochure (Imperial) Technical data for CD-2600 EX (MRP) in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download
CD-2600 EX (MFS) *Pharma - Dry Recovery
ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X - T135oC
LCIE 03 ATEX 6295
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822. Or ULPA Filter - Optional with an efficiency of 99.999% on 0.12 micron. Tested: IEST RP-CC001.3. Filtration efficiency of 99.9995% on 0.18 micron. Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.
  • *Cleanroom compatible. Can be used in the pharmaceutical industry
  • Designed for general cleanup in hazardous locations
  • Continuous duty single or 3-phase explosion proof/dust ignition proof motor
  • Available with Manual Filter Shaker (MFS)
  • Available in a fixed or mobile unit
  • All stainless steel AISI 304/316 construction
  • For dry recovery only (liquids can be recovered into a separate tank)
  • Detachable recovery tank (DT) for easy disposal of recovered materials. Recovery capacity of9.5 gallons (36 liters)
  • Unit is compact with small footprint
  • Equipped with 4 wheels
All stainless steel construction.  Less than 10 Ohms of resistivity.   This unit is available with an optional true HEPA (H14) / ULPA (U15) Filter located downstream outside of the motor housing.  This unit is cleanroom compatible and can be used in the pharmaceutical industry.  Available with Manual Filter Shaker (MFS).  The vacuum cleaner is mounted on 4 wheels with locks for easy manoeuverability and facilitates access to processing equipment when used as a mobile unit.  All of our ULPA vacuum cleaners are DOP Leak Tested before leaving our facility.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.99% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 micron or larger.

North-America: Each HEPA Filter has a minimum filtration efficiency of 99.99% on 0.3 micron.  Tested as per IES-RP-CC001.3.

Europe: Each HEPA Filter has a minimum filtration efficiency of 99.995% on 0.3 micron, rated H14 as per EN 1822 by MPPS method.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron.  Tested as per IES-RP-CC001.3.

Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.

MFS - Manual Filter Shaker System

MFS_top
(illustration shows a top-mounted shaker)

The Manual Fitler Shaker system allows the operator to clean the main filter without having to open the vacuum cleaner.  This shaker System reduces maintenance down time.

The Manual Filter Shaker System consists of a spring action mechanism operating directly onto the filter cage located inside of the filter chamber. The system is operated by pressing on the ergonomic handle located on the side or top of the filter chamber.

The Manual Filter Shaker dislodges the accumulated caked-on dust from the filter thus improving the filter’s performance.

The filter, along with the filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

DT - Detachable Recovery Tank

detachable-tankMany of our vacuum cleaners come equipped with a detachable tank for the easy disposal of recovered materials. Our detachable tanks range in size from 20 to 160 liters (5.28 gal to 42.25 gal) and are available in stainless steel or powder coated, with or without wheels for maneuverability.

Name Description Download
CD-2600 EX (MFS) Brochure (Metric) Technical data for CD-2600 EX (MFS) in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-2600 EX (MFS) Brochure (Imperial) Technical data for CD-2600 EX (MFS) in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download
CD-2 EX (MRAC) *Pharma - Wet & Dry
ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X - T135oC
LCIE 03 ATEX 6295
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • ULPA Filter - Included with an efficiency of 99.999% on 0.12 micron. Tested: IEST RP-CC001.3. Filtration efficiency of 99.9995% on 0.18 micron. Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • For general cleanup in hazardous locations
  • Continuous duty single or 3-phase explosion proof/dust ignition proof motor
  • Available for wet and dry recovery
  • Available with middle ring (MRAC) with activated carbon
  • All stainless steel 304/316 construction
  • Liquid recovery capacity of 12.5 gallons (47.5 liters)
  • Equipped with a 4-wheel cart for easy manoeuverability
All stainless steel AISI 304/316 construction.  Less than 10 Ohms of resistivity.  This unit contains a true ULPA Filter (U15) located downstream outside of the motor housing.  This unit is cleanroom compatible and can be used in the pharmaceutical industry.  This unit can be used for general maintenance in hazardous locations.  This unit is available with a Middle Ring for wet and dry recovery.  An Activated Carbon Cartridge is also available for the adsorption of toxic fumes and vapors.  All of our ULPA vacuum cleaners are DOP Leak Tested before leaving our facility

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron.  Tested as per IES-RP-CC001.3.

Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.

MRAC - Middle Ring with Activated Carbon

Activated carbon is used for the adsorption of toxic/nuisance fumes and vapors. Tiger-Vac offers a variety of activated carbons for the recovery of fuels, mercury, chloride and acid vapors and for Arsine and Phosphine.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

Name Description Download
CD-2 EX (MRAC) Brochure (Metric) Technical data for CD-2 EX (MRAC) in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-2 EX (MRAC) Brochure (Imperial) Technical data for CD-2 EX (MRAC) in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download
CD-3 EX Series (Wet & Dry) *Pharma - Wet & Dry
ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X - T135oC
LCIE 03 ATEX 6295
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • ULPA Filter - Included with an efficiency of 99.999% on 0.12 micron. Tested: IEST RP-CC001.3. Filtration efficiency of 99.9995% on 0.18 micron. Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • For general cleanup in hazardous locations
  • Continuous duty 3-phase explosion proof/dust ignition proof motor
  • Wet and dry recovery
  • Available with Middle Ring with Activated Carbon (MRAC).  Several types of carbon are available
  • Available with Liquid Bath Immersion system for the recovery of metallic/combustible dusts
  • All stainless steel 304/316 construction
  • Liquid recovery capacity of 17 gallons (65 liters)
  • Equipped with a 4-wheel cart for easy manoeuverability
All stainless steel AISI 304/316 construction.  Less than 10 Ohms of resistivity.  This unit contains a true ULPA Filter (U15) lcoated downstream outside of the motor housing.  This unit is cleanroom compatible and can be used for the pharmaceutical industry.  This unit can be used for general maintenance in hazardous locations.  This unit is also available with a Middle Ring with Activated Carbon (MRAC) for wet and dry recovery as well as a version with a Liquid Bath Immersion system for the recovery of metallic/combustible dusts.  An Activated Carbon Cartridge is also available for the adsorption of toxic fumes and vapors.  Several different types of carbon are available.  All of our ULPA vacuum cleaners are DOP Leak Tested before leaving our facility.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron.  Tested as per IES-RP-CC001.3.

Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.

MRAC - Middle Ring with Activated Carbon

Activated carbon is used for the adsorption of toxic/nuisance fumes and vapors. Tiger-Vac offers a variety of activated carbons for the recovery of fuels, mercury, chloride and acid vapors and for Arsine and Phosphine.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

Name Description Download
CD-3 EX Series (Wet & Dry) Brochure (Metric) Technical data for CD-3 EX Series (Wet & Dry) in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-3 EX Series (Wet & Dry) Brochure (Imperial) Technical data for CD-3 EX Series (Wet & Dry) in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download
CD-115V EX DT MFS Dry Recovery
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • HEPA Filter - Optional with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
  • Static dissipating PTFE bell shapped Main Filter
  • Designed for general cleanup
  • Continuous duty single phase explosion proof/dust ignition proof motor
  • Equipped with a Manual Filter Shaker (MFS) system
  • For dry recovery only
  • All stainless steel AISI 304 construction (except cart)
  • Detachable recovery tank (DT) for easy disposal of recovered materials.  Recovery capacity of 10 gallons (40 liters)
  • Equipped with 4-wheel cart for easy manoeuverability
  • Includes a complete static dissipative tool kit

All stainless steel AISI 304 construction (except cart).  Less than 10 Ohms of resistivity.  This unit is available with an optional upstream true HEPA (H14) Filter with housing.  This unit is equipped with a static dissipating bell shapped PTFE filter and Manual Filter Shaker (MFS) system.  This unit is also equipped with a maintenance free, beltless side chanel blower with a 25000 hour lifespan.  The single phase explosion proof/dust ignition proof motor is fully enclosed in a protective cabinet.  This unit can be used for general maintenance in hazardous locations.  Equipped with a disposable filter bag for the easy and safe disposal of recovered materials.  All of our HEPA vacuum cleaners are DOP Leak Tested before leaving our facility.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.99% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 micron or larger.

North-America: Each HEPA Filter has a minimum filtration efficiency of 99.99% on 0.3 micron.  Tested as per IES-RP-CC001.3.

Europe: Each HEPA Filter has a minimum filtration efficiency of 99.995% on 0.3 micron, rated H14 as per EN 1822 by MPPS method.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

MFS - Manual Filter Shaker System

MFS_top
(illustration shows a top-mounted shaker)

The Manual Fitler Shaker system allows the operator to clean the main filter without having to open the vacuum cleaner.  This shaker System reduces maintenance down time.

The Manual Filter Shaker System consists of a spring action mechanism operating directly onto the filter cage located inside of the filter chamber. The system is operated by pressing on the ergonomic handle located on the side or top of the filter chamber.

The Manual Filter Shaker dislodges the accumulated caked-on dust from the filter thus improving the filter’s performance.

The filter, along with the filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

DT - Detachable Recovery Tank

detachable-tankMany of our vacuum cleaners come equipped with a detachable tank for the easy disposal of recovered materials. Our detachable tanks range in size from 20 to 160 liters (5.28 gal to 42.25 gal) and are available in stainless steel or powder coated, with or without wheels for maneuverability.

Name Description Download
CD-115V EX DT MFS Brochure (Metric) Technical data for CD-115V EX DT MFS in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-115V EX DT MFS Brochure (Imperial) Technical data for CD-115V EX DT MFS in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-230V EX DT MFS Dry Recovery
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • HEPA Filter - Optional with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
  • Static dissipating PTFE bell shapped Main Filter
  • Designed for general cleanup
  • Continuous duty single phase explosion proof/dust ignition proof motor
  • Equipped with a Manual Filter Shaker (MFS) system
  • For dry recovery only
  • All stainless steel AISI 304 construction (except cart)
  • Detachable recovery tank (DT) for easy disposal of recovered materials.  Recovery capacity of 10 gallons (40 liters)
  • Equipped with 4-wheel cart for easy manoeuverability
  • Includes a complete static dissipative tool kit
All stainless steel AISI 304 construction (except cart).  Less than 10 Ohms of resistivity.  This unit is available with an optional true HEPA (H14) Filter.  This unit is equipped with a static dissipating bell shapped PTFE filter and Manual Filter Shaker (MFS) system.  This unit is also equipped with a maintenance free, beltless side chanel blower with a 25000 hour lifespan.  The single phase explosion proof/dust ignition proof motor is fully enclosed in a protective cabinet.  This unit can be used for general maintenance in hazardous locations.  Equipped with a disposable filter bag for the easy and safe disposal of recovered materials.  All of our HEPA vacuum cleaners are DOP Leak Tested before leaving our facility.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.99% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 micron or larger.

North-America: Each HEPA Filter has a minimum filtration efficiency of 99.99% on 0.3 micron.  Tested as per IES-RP-CC001.3.

Europe: Each HEPA Filter has a minimum filtration efficiency of 99.995% on 0.3 micron, rated H14 as per EN 1822 by MPPS method.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

MFS - Manual Filter Shaker System

MFS_top
(illustration shows a top-mounted shaker)

The Manual Fitler Shaker system allows the operator to clean the main filter without having to open the vacuum cleaner.  This shaker System reduces maintenance down time.

The Manual Filter Shaker System consists of a spring action mechanism operating directly onto the filter cage located inside of the filter chamber. The system is operated by pressing on the ergonomic handle located on the side or top of the filter chamber.

The Manual Filter Shaker dislodges the accumulated caked-on dust from the filter thus improving the filter’s performance.

The filter, along with the filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

DT - Detachable Recovery Tank

detachable-tankMany of our vacuum cleaners come equipped with a detachable tank for the easy disposal of recovered materials. Our detachable tanks range in size from 20 to 160 liters (5.28 gal to 42.25 gal) and are available in stainless steel or powder coated, with or without wheels for maneuverability.

Name Description Download
CD-230V EX DT MFS Brochure (Metric) Technical data for CD-230V EX DT MFS in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-230V EX DT MFS Brochure (Imperial) Technical data for CD-230V EX DT MFS in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-4000 EX (MFS) Dry Recovery
ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X - T135oC
LCIE 03 ATEX 6295
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • HEPA Filter - Optional with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
  • Static dissipating PTFE bell shapped Main Filter
  • Designed for general cleanup
  • Continuous duty 3-phase explosion proof/dust ignition proof motor
  • Equipped with a Manual Filter Shaker (MFS) system
  • For dry recovery only
  • All stainless steel AISI 304 construction (except cart)
  • Detachable recovery tank (DT) for easy disposal of recovered materials.  Recovery capacity of 17 gallons (65 liters)
  • Equipped with 4-wheel cart for easy manoeuverability
  • Includes a complete static dissipative tool kit
All stainless steel AISI 304 construction (except cart).  Less than 10 Ohms of resistivity.  This unit is available with an optional true HEPA (H14) Filter.  This unit is equipped with a static dissipating bell shapped PTFE filter and Manual Filter Shaker (MFS) system.  This unit is also equipped with a maintenance free, beltless side chanel blower with a 25000 hour lifespan.  The 3-phase explosion proof/dust ignition proof motor is fully enclosed in a protective cabinet.  This unit can be used for general maintenance in hazardous locations.  Equipped with a disposable filter bag for the easy and safe disposal of recovered materials.  All of our HEPA vacuum cleaners are DOP Leak Tested before leaving our facility.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.99% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 micron or larger.

North-America: Each HEPA Filter has a minimum filtration efficiency of 99.99% on 0.3 micron.  Tested as per IES-RP-CC001.3.

Europe: Each HEPA Filter has a minimum filtration efficiency of 99.995% on 0.3 micron, rated H14 as per EN 1822 by MPPS method.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

MFS - Manual Filter Shaker System

MFS_top
(illustration shows a top-mounted shaker)

The Manual Fitler Shaker system allows the operator to clean the main filter without having to open the vacuum cleaner.  This shaker System reduces maintenance down time.

The Manual Filter Shaker System consists of a spring action mechanism operating directly onto the filter cage located inside of the filter chamber. The system is operated by pressing on the ergonomic handle located on the side or top of the filter chamber.

The Manual Filter Shaker dislodges the accumulated caked-on dust from the filter thus improving the filter’s performance.

The filter, along with the filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

DT - Detachable Recovery Tank

detachable-tankMany of our vacuum cleaners come equipped with a detachable tank for the easy disposal of recovered materials. Our detachable tanks range in size from 20 to 160 liters (5.28 gal to 42.25 gal) and are available in stainless steel or powder coated, with or without wheels for maneuverability.

Name Description Download
CD-4000 EX (MFS) Brochure (Metric) Technical data for CD-4000 EX (MFS) in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-4000 EX (MFS) Brochure (Imperial) Technical data for CD-4000 EX (MFS) in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download
CD-4000 EX Brochure Model Brochure download
CD-5 EX SERIES *Pharma - Dry Recovery
ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X - T135oC
LCIE 03 ATEX 6295
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822. Or ULPA Filter - Optional with an efficiency of 99.999% on 0.12 micron. Tested: IEST RP-CC001.3. Filtration efficiency of 99.9995% on 0.18 micron. Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • Continuous duty 3-phase explosion proof/dust ignition proof motor
  • Manual or fully automatic filtration cleaning systems
  • All Stainless Steel AISI 304 construction (AISI 316 electropolished available)
  • For dry recovery (liquids can be recovered into a separate tank)
  • Detachable recovery tank (DT) for easy disposal of recovered materials
  • Declaration of conformity
All stainless steel construction.  Equipped with a continuous duty 3-phase explosion proof/dust ignition proof motor.  Less than 10 Ohms of resistivity.  These units can also be equipped with true HEPA Filters (H14)/ULPA Filters (U15) located upstream and/or downstream of the motor.  This unit can be used for general maintenance in hazardous locations and is designed to be either a portable or stationary unit.  This unit is cleanroom compatible and can be used in the pharmaceutical industry.  This unit can be equipped with one of 5 filtration systems - Manual Filters Shaker (MFS), Manual Reverse Purge (MRP), Automatic Filter Shaker (AFS), Automatic Reverse Pulse (RPS) or Automatic Purge System (APS).  These filtration systems enable the operator to clean the internal filters/cartridges without having to open up the vacuum cleaner.  These filtration systems reduce maintenance downtime.  All of our HEPA vacuum cleaners are DOP Leak Tested before leaving our facility.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.99% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 micron or larger.

North-America: Each HEPA Filter has a minimum filtration efficiency of 99.99% on 0.3 micron.  Tested as per IES-RP-CC001.3.

Europe: Each HEPA Filter has a minimum filtration efficiency of 99.995% on 0.3 micron, rated H14 as per EN 1822 by MPPS method.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron.  Tested as per IES-RP-CC001.3.

Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.

APS - Automatic Purge system

Explosion proof Automatic Purge system (Pneumatic Timers)

APS_control_panel
A full immersion system for hazardous areas, consisting of a round header tank with fully integrated diaphragm valves, is built inside of the filter chamber. The system operates with filtered, oil-free compressed air. The diaphragm valves are opened in sequence by a solenoid valve controlled by pneumatic (air) operated timers located outside of the filter chamber.

A short pulse of compressed air is injected into the top of theStatic dissipating and conductive PTFE laminated filter catridges creating a stronger airflow downward moving pressure wave. This wave breaks up the accumulated dust that is caked onto the cartridges.

The pneumatically (air) operated controls, located outside of the filter chamber, allow only one cartridge to be cleaned at any give time, thus ensuring that the vacuum cleaner operates continuously.

Industrial Automatic Purge System (Electric Timers)

auto_pulse

A short pulse of compressed air is injected into the top of the filter cartridges creating a stronger wave of airflow pressure which moves downward into the filters and breaks up the accumulated dust that is caked onto the cartridges.

The electrically operated controls, located outside of the filter chamber, allow only one cartridge to be cleaned at any give time, thus ensuring that the vacuum cleaner operates continuously.

AFS - Automatic Filter Shaker

AFS_control_panelA Filter Shaker system for hazardous areas consisting of a double acting air cylinder operating directly onto the stainless steel filter cage located inside of the filter chamber. The system is operated by filtered, oil-free compressed air. The frequency of the shaking cycle is controlled by pneumatic (air) operated timers located outside of the filter chamber.

Short strokes are applied to the filter cage freeing the accumulated caked on dust from the Static dissipating and conductive polyester flourocarbon treated filter and allowing them to flow out, thus ensuring continuous duty and minimizing friction loss filter performance.

The Static dissipating and conductive polyester flourocarbon treated filter, along with the stainless steel filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.

MFS - Manual Filter Shaker System

MFS_top
(illustration shows a top-mounted shaker)

The Manual Fitler Shaker system allows the operator to clean the main filter without having to open the vacuum cleaner.  This shaker System reduces maintenance down time.

The Manual Filter Shaker System consists of a spring action mechanism operating directly onto the filter cage located inside of the filter chamber. The system is operated by pressing on the ergonomic handle located on the side or top of the filter chamber.

The Manual Filter Shaker dislodges the accumulated caked-on dust from the filter thus improving the filter’s performance.

The filter, along with the filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.

RPS - Reverse Pulse System

RPS

  • Automatic filter cleaning system that helps remove caked-on dust from the filter.
  • Pulsed air is blown from the inside towards the outside of the filter at a regular frequence.
  • User can adjust the interval between the two cleaning cycles.
  • Pneumatically (air) operated.

MRP - Manual Reverse Purge System

MRP The Manual Reverse Purge (MRP) System allows the operator to not have to open the vacuum cleaner in order to clean the Cartridge. By opening the Reverse Purge Atmospheric Pressure Release Valve the Cartridge is automatically purged of dusts. This Purging System reduces maintenance down time.

The Manual Reverse Purge (MRP) works by :

1 - Closing the slider on the opening to block the suction intake orifice for approximately 5 seconds while the vacuum is running.

2 - Then quickly open Purge Valve. Air is now flowing via the valve through to the filter.

Keep Purge Valve open for 1-2 seconds then close (repeat above steps 2 or 3 times).

Reverse Purge System will cause dust to fall off of the filter.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

DT - Detachable Recovery Tank

detachable-tankMany of our vacuum cleaners come equipped with a detachable tank for the easy disposal of recovered materials. Our detachable tanks range in size from 20 to 160 liters (5.28 gal to 42.25 gal) and are available in stainless steel or powder coated, with or without wheels for maneuverability.

Name Description Download
CD-5 EX SERIES Brochure (Metric) Technical data for CD-5 EX SERIES in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-5 EX SERIES Brochure (Imperial) Technical data for CD-5 EX SERIES in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download
CD-7 EX Extended SERIES *Pharma - Dry Recovery
ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X - T135oC
LCIE 03 ATEX 6295
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822. Or ULPA Filter - Optional with an efficiency of 99.999% on 0.12 micron. Tested: IEST RP-CC001.3. Filtration efficiency of 99.9995% on 0.18 micron. Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • Continuous duty 3-phase explosion proof/dust ignition proof motor
  • Manual or automatic filtration cleaning systems
  • All Stainless Steel AISI 304 construction (AISI 316 electropolished available)
  • For dry recovery (liquids can be recovered into a separate tank)
  • Detachable recovery tank (DT) for easy disposal of recovered materials
  • Declaration of conformity
All stainless steel construction.  Equipped with a continuous duty 3-phase explosion proof/dust ignition proof motor.  Less than 10 Ohms of resistivity.  These units can also be equipped with true HEPA Filters (H14)/ULPA Filters (U15) located upstream and/or downstream of the motor.  This unit can be used for general maintenance in hazardous locations and is designed to be either a portable or stationary unit.  This unit is cleanroom compatible and can be used in the pharmaceutical industry.  This unit can be equipped with one of 3 filtration systems - Manual Filters Shaker (MFS), Manual Reverse Purge (MRP), Automatic Reverse Purge System (ARP).  These filtration systems enable the operator to clean the internal filters/cartridges without having to open up the vacuum cleaner.  These filtration systems reduce maintenance downtime.  All of our HEPA vacuum cleaners are DOP Leak Tested before leaving our facility.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.99% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 micron or larger.

North-America: Each HEPA Filter has a minimum filtration efficiency of 99.99% on 0.3 micron.  Tested as per IES-RP-CC001.3.

Europe: Each HEPA Filter has a minimum filtration efficiency of 99.995% on 0.3 micron, rated H14 as per EN 1822 by MPPS method.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron.  Tested as per IES-RP-CC001.3.

Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.

ARP - Automatic Reverse Purge

ARP

The Automatic Reverse Purge System requires a small 2 HP compressor on a 1/4" air line hose @ 5 bar (80 psi), 3.78 l/s (8 cfm) to feed the system. This system is ideal when the vacuum cleaner will be attached to a processing system and the operator does not have the time to continually perform a manual purge. A flap has been installed inside of the suction port and will close automatically when the vacuum cleaner is turned off, thus eliminating the risk that any powders or debris will escape from the unit when operating the ARP without any suction power.

MFS - Manual Filter Shaker System

MFS_top
(illustration shows a top-mounted shaker)

The Manual Fitler Shaker system allows the operator to clean the main filter without having to open the vacuum cleaner.  This shaker System reduces maintenance down time.

The Manual Filter Shaker System consists of a spring action mechanism operating directly onto the filter cage located inside of the filter chamber. The system is operated by pressing on the ergonomic handle located on the side or top of the filter chamber.

The Manual Filter Shaker dislodges the accumulated caked-on dust from the filter thus improving the filter’s performance.

The filter, along with the filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.

MRP - Manual Reverse Purge System

MRP The Manual Reverse Purge (MRP) System allows the operator to not have to open the vacuum cleaner in order to clean the Cartridge. By opening the Reverse Purge Atmospheric Pressure Release Valve the Cartridge is automatically purged of dusts. This Purging System reduces maintenance down time.

The Manual Reverse Purge (MRP) works by :

1 - Closing the slider on the opening to block the suction intake orifice for approximately 5 seconds while the vacuum is running.

2 - Then quickly open Purge Valve. Air is now flowing via the valve through to the filter.

Keep Purge Valve open for 1-2 seconds then close (repeat above steps 2 or 3 times).

Reverse Purge System will cause dust to fall off of the filter.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

DT - Detachable Recovery Tank

detachable-tankMany of our vacuum cleaners come equipped with a detachable tank for the easy disposal of recovered materials. Our detachable tanks range in size from 20 to 160 liters (5.28 gal to 42.25 gal) and are available in stainless steel or powder coated, with or without wheels for maneuverability.

Name Description Download
CD-7 EX Extended SERIES Brochure (Metric) Technical data for CD-7 EX Extended SERIES in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-7 EX Extended SERIES Brochure (Imperial) Technical data for CD-7 EX Extended SERIES in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download
CD-10 EX SERIES Pharma* - Dry Recovery
ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X - T135oC
LCIE 03 ATEX 6295
  • Legally certified explosion proof/dust ignition proof vacuum cleaner
  • Less than 10 Ohms of resistivity
  • HEPA Filter - Included with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822. Or ULPA Filter - Optional with an efficiency of 99.999% on 0.12 micron. Tested: IEST RP-CC001.3. Filtration efficiency of 99.9995% on 0.18 micron. Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822.
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • Continuous duty 3-phase explosion proof/dust ignition proof motor
  • Manual or fully automatic filtration cleaning systems
  • All Stainless Steel AISI 304 construction (AISI 316 electropolished available)
  • For dry recovery (liquids can be recovered into a separate tank)
  • Detachable recovery tank (DT) for easy disposal of recovered materials
  • Declaration of conformity

All stainless steel construction.  Equipped with a continuous duty 3-phase explosion proof/dust ignition proof motor.  Less than 10 Ohms of resistivity.  These units can also be equipped with true HEPA Filters (H14)/ULPA Filters (U15) located upstream and/or downstream of the motor.  This unit can be used for general maintenance in hazardous locations and is designed to be either a portable or stationary unit.  This unit is cleanroom compatible and can be used in the pharmaceutical industry.  This unit can be equipped with one of 3 filtration systems - Automatic Filter Shaker (AFS), Automatic Reverse Pulse (RPS) or Automatic Purge System (APS).  These filtration systems enable the operator to clean the internal filters/cartridges without having to open up the vacuum cleaner.  These filtration systems reduce maintenance downtime.  All of our HEPA vacuum cleaners are DOP Leak Tested before leaving our facility.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.99% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 micron or larger.

North-America: Each HEPA Filter has a minimum filtration efficiency of 99.99% on 0.3 micron.  Tested as per IES-RP-CC001.3.

Europe: Each HEPA Filter has a minimum filtration efficiency of 99.995% on 0.3 micron, rated H14 as per EN 1822 by MPPS method.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron.  Tested as per IES-RP-CC001.3.

Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.

APS - Automatic Purge system

Explosion proof Automatic Purge system (Pneumatic Timers)

APS_control_panel
A full immersion system for hazardous areas, consisting of a round header tank with fully integrated diaphragm valves, is built inside of the filter chamber. The system operates with filtered, oil-free compressed air. The diaphragm valves are opened in sequence by a solenoid valve controlled by pneumatic (air) operated timers located outside of the filter chamber.

A short pulse of compressed air is injected into the top of theStatic dissipating and conductive PTFE laminated filter catridges creating a stronger airflow downward moving pressure wave. This wave breaks up the accumulated dust that is caked onto the cartridges.

The pneumatically (air) operated controls, located outside of the filter chamber, allow only one cartridge to be cleaned at any give time, thus ensuring that the vacuum cleaner operates continuously.

Industrial Automatic Purge System (Electric Timers)

auto_pulse

A short pulse of compressed air is injected into the top of the filter cartridges creating a stronger wave of airflow pressure which moves downward into the filters and breaks up the accumulated dust that is caked onto the cartridges.

The electrically operated controls, located outside of the filter chamber, allow only one cartridge to be cleaned at any give time, thus ensuring that the vacuum cleaner operates continuously.

AFS - Automatic Filter Shaker

AFS_control_panelA Filter Shaker system for hazardous areas consisting of a double acting air cylinder operating directly onto the stainless steel filter cage located inside of the filter chamber. The system is operated by filtered, oil-free compressed air. The frequency of the shaking cycle is controlled by pneumatic (air) operated timers located outside of the filter chamber.

Short strokes are applied to the filter cage freeing the accumulated caked on dust from the Static dissipating and conductive polyester flourocarbon treated filter and allowing them to flow out, thus ensuring continuous duty and minimizing friction loss filter performance.

The Static dissipating and conductive polyester flourocarbon treated filter, along with the stainless steel filter cage, can be easily removed from the filter chamber and washed with lukewarm water and mild detergents.

RPS - Reverse Pulse System

RPS

  • Automatic filter cleaning system that helps remove caked-on dust from the filter.
  • Pulsed air is blown from the inside towards the outside of the filter at a regular frequence.
  • User can adjust the interval between the two cleaning cycles.
  • Pneumatically (air) operated.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

DT - Detachable Recovery Tank

detachable-tankMany of our vacuum cleaners come equipped with a detachable tank for the easy disposal of recovered materials. Our detachable tanks range in size from 20 to 160 liters (5.28 gal to 42.25 gal) and are available in stainless steel or powder coated, with or without wheels for maneuverability.

Name Description Download
CD-10 EX SERIES Brochure (Metric) Technical data for CD-10 EX SERIES in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CD-10 EX SERIES Brochure (Imperial) Technical data for CD-10 EX SERIES in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download
CDPU-5/7/10 EX *Pharma - Continuous Duty Power Unit
ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X - T135oC
LCIE 03 ATEX 6295
  • Legally certified explosion proof/dust ignition proof vacuum cleaner. 
  • Less than 10 Ohms of resistivity
  • ULPA Filter - Included with an efficiency of 99.999% on 0.12 micron. Tested: IEST RP-CC001.3. Filtration efficiency of 99.9995% on 0.18 micron. Tested: IEST RP-CC001.3. U15 by MPPS method as per EN 1822. Or HEPA Filter - Optional with an efficiency of 99.995% on 0.3 micron. Tested: IEST RP-CC001.3. H14 by MPPS method as per EN 1822.
  • *Cleanroom compatible.  Can be used in the pharmaceutical industry
  • Continuous duty 3-phase explosion proof motor
  • Power Unit can be attached to a Filtration System (FRS)
  • Can be used as a mobile or central unit
  • All stainless steel construction
  • Equipped with 4 wheels for easy manoeuverability.  Can also be equipped with slots for fork lift capability
All stainless steel construction.  Less than 10 Ohms of resistivity.  This unit can be equipped with a true ULPA Filter (U15) or HEPA Filter (H14) located either downstream or upstream outside of the motor housing.  This unit is cleanroom compatible and can be used in the pharmaceutical industry.  This unit can be used in hazardous locations and can be used as either a mobile or central unit.  It can also be hooked up to a Filtration System (FRS).  All of our ULPA/HEPA Power Units are DOP Leak Tested before leaving our facility.

HEPA - High Efficiency Particulate Air Filter

A HEPA filter is a type of air filter, which means it filters the air coming in or out of the vacuum cleaner system. It can remove at least 99.99% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.3 micron or larger.

North-America: Each HEPA Filter has a minimum filtration efficiency of 99.99% on 0.3 micron.  Tested as per IES-RP-CC001.3.

Europe: Each HEPA Filter has a minimum filtration efficiency of 99.995% on 0.3 micron, rated H14 as per EN 1822 by MPPS method.

Click here to download Tiger-Vac's HEPA Filter's standards chart.

ULPA - Ultra Low Penetration Air Filter

A ULPA filter is a type of air filter. It can remove at least 99.999% of dust, pollen, mould, bacteria and any other airborn particles with a size of 0.12 microns or larger.

North-America: Each ULPA Filter has a minimum filtration efficiency of 99.999% on 0.12 micron.  Tested as per IES-RP-CC001.3.

Europe: Each ULPA Filter has a minimum filtration efficiency of 99.9995% on 0.18 micron, rated U15 as per EN 1822 by MPPS method.

10 Ohms - Explosion Proof Requirement

In order for Tiger-Vac to legally certify an Explosion Proof/Dust Ignition Proof vacuum cleaner system the unit must be static dissipative (SD*) and conductive and have a resistivity measuring less than 10 Ohms from the grounded air supply hose to any point on the vacuum cleaner system.  This makes the unit eligible to be Explosion Proof/Dust Ignition Proof and be part of Tiger-Vac's quality control management system ISO 9001:2000.

When using a pneumatic Explosion Proof Vacuum Cleaner System the customer must make sure that the source of air supply (compressor) is grounded.

Name Description Download
CDPU-5/7/10 EX Brochure (Metric) Technical data for CDPU-5/7/10 EX in metric units (Millimeters, Kilograms...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
CDPU-5/7/10 EX Brochure (Imperial) Technical data for CDPU-5/7/10 EX in imperial units (Inches, Pounds...) Brochure Letter (8½" × 11")

Brochure A4 (210mm × 297mm)
ATEX Vacuum Cleaners electrically operated triphase to be used in Hazardous Areas Certification Document download

Note:

HEPA Filters - efficiency of 99.995% on 0.3 microns - Tested IEST RP-CC001.3 - H14 as per MPPS method EN 1822.

ULPA Filters - efficiency of 99.999% on 0.3 microns - Filtration efficiency of 99.9995% on 0.18 microns - Tested IEST RP-CC001.3 - U15 as per MPPS method EN 1822

Please be advised that all Tiger-Vac HEPA/ULPA Filters are DOP tested when assembled, either upstream or downstream, inside of the vacuum cleaners.

All Tiger-Vac HEPA/ULPA Filters are assembled mechanically with 3 bolts and include a specially designed memory gasket in order to prevent any leaks during the life span of the gasket thus insuring the health and safety of the end user.













 
With forty years of experience, Tiger-Vac has successfully established itself in the international market as a manufacturer of high-quality industrial, explosion proof, cleanroom and ATEX, IECEx, NFPA-NEC compliant vacuum cleaner systems for contamination controlled environments & hazardous areas.
ex-mat-logo