E-Mail Drucken PDF
ex-mat-logo

Tiger-Vac, as the manufacturer, GUARANTEES, that these units can be used to safely recover combustible /conductive dusts and/or flammable liquids.

The ATEX marking certifies only, by it's Ingress of Protection (IP),  the capacity of the vacuum cleaner to be in the presence of combustible /conductive dusts and/or flammable liquids but does not certify the capacity of the vacuum cleaner to recover them.

Industrial Vacuum Cleaner Systems
For Bakery Oven Cleaning

rocko-at-the-oven-2Tiger-Vac is pleased to present its new line of vacuum cleaners for cleaning ovens in artistic and industrial bakeries, for recovering hot crumbs only.

Tiger-Vac’s line of vacuum cleaners ensures without dispersion, as opposed to sweeping, the recovery of powdered flour which is the leading cause of respiratory allergies in bakeries.

Tiger-Vac’s line of vacuum cleaners ensure health and safety

Tiger-Vac’s line of vacuum cleaners allow for rapid, thorough and safe cleaning of powders which cause respiratory allergies in bakeries, while still conforming, in particular, to the ATEX directives concerning high risk zones.

Different applications

  1. Single phase models TV-27, non-ATEX, and ATEX 22E with optional accessories Kit #2 are designed to recover hot powders and crumbs inside ovens.
  2. For the recovery of flour, Tiger-Vac would like to propose our single phase model EXP1-20L DT certified ATEX Category 2 Zone 21, 22 (dust) and also Zone 1,2 (gas). When equipped with optional accessories Kit #2, can be used to recover hot powders and crumbs inside ovens.

Flour is a product known to be explosive. In order to recover flour without risk, it is necessary to use a vacuum cleaner that is ATEX certified by a notified independent testing laboratory that conforms to ATEX directives concerning high risk zones.

We invite you to review the line of vacuum cleaners designed by Tiger-Vac for bakery oven cleaning and to contact us with any questions or requests for further information that you may have.

TV-27Model TV-27 with
oven tool kit #1 included
Non-ATEX Vacuum

 

Specifications

For oven cleaning up to 150oC

  • for recovering hot crumbs in artisanal bakeries
  • Power Performance of 1050 W
  • Stainless steel recovery tank. 27 liters.
  • Includes Oven Cleaning Tool Kit and high temperature Main Filter
  • Optional Standard Tool Kit and Main Filter Part no 381481 available
  • Brochure

Tool Kit #1 included with TV-27

oven_toolkit_1

ATEX22E_largeModel ATEX-22E

ce-markex_markII 3 D Ex tD A22 IP6X T100°C

 

 

Specifications

Vacuum cleaner certified ATEX Category 3 for use in Zone 22 (IP6X)

  • Power performance of 1050 W
  • Equipped with a "By-Pass" motor
  • Stainless steel recovery tank with a capacity of 35 liters with a paper filter bag with a capacity of 20 liters
  • Includes ATEX 22 accessories kit
  • Oven Cleaning Kit and High Temperature Filter optional
  • Brochure

 

EXP1-20-DT-masked-45-degModel EXP1-20L DT

ce-mark 0081 ex_mark II 2 G/D EEx d IIB T4
IP6X – T135°C
LCIE 03 ATEX 6295

Code# 110364B (240V)

Specifications

Vacuum cleaner certified ATEX Category 2 for use in Zones 21 and 22 (IP65)

  • Single phase model, available only at Tiger-Vac. 3-Phase version available
  • Includes conductive ATEX 21 accessories (resistance of less than 10 ohms)
  • Power performance of 1100 W
  • All stainless steel AISI 304 construction
  • Recovery tank capacity of 25 liters. 35 and 60 liter recovery tanks also available
  • Certified by LCIE - a notified ATEX independent testing laboratory
  • Brochure

 

Tool kit #2 optional for models ATEX-22E & EXP1-20L DT

oven_toolkit_2

Notes:

1. Other models with more power and larger recovery capacities are available upon request.
Pneumatically (air) operated models available.

2. ATEX Category 3 vacuum cleaners can be used in Zone 22 in the presence of flour but cannot be used to recover flour (please see the definition for Zone 22 in Annex I of ATEX Directive 1999/92/CE)

Only Category 2 vacuum cleaners designed for use in Zones 21 and 22 can be used to recover flour

In Zone 22, Category 2 and/or 3 vacuum cleaners can be used depending on the application required

Please see selection criteria in Annex II of ATEX Directive 1999/92/CE.


TYPE 22 VACUUM CLEANERS

ATTENTION:

Vacuum cleaners advertised as « Type 22 » are commercial vacuum cleaners which do not hold any official certification for use in hazardous areas.

« Type 22 » vacuum cleaners are not recognized by ATEX Directives applicable in Europe, nor by the certification group IECex which is applicable Internationally, nor by NFPA regulations applicable in North America.

The « Type 22 » vacuum cleaner was designed purely for commercial reasons in order to confuse and mislead the public regarding equipment designed specifically for use in an ATEX Zone 22 hazardous location and equipment designed for use in commercial establishments such as hotels and restaurants.

Vacuum cleaners advertised as « Type 22 » are dangerous when used in hazardous areas as they have been designed to be used in hotels and restaurants to clean out grease traps and washrooms.

DEFINITION OF A ZONE 22 ACCORDING TO ANNEX I OF ATEX DIRECTIVE 1999/92/CE

 

A: Zone 22

A place in which an explosive atmosphere in the form of a cloud of combustible dust in air is not likely to occur in normal operation but, if it does occur, will persist for a short period only.

Self-certified ATEX Category 3 vacuum cleaners for use in ATEX Zone 22 hazardous areas have been designed to be used in the presence of combustible dusts but not to recover combustible dusts.

B: Category 3 as defined in the Directive 94/9/EC

Comprises equipment designed to be capable of functioning in conformity with the operating parameters established by the manufacturer and ensuring a normal level of protection.

Equipment in this category is intended for use in areas in which explosive atmospheres caused by gases, vapors, mists, or air/dust mixtures are unlikely to occur or, if they do occur, are likely to do so only infrequently and for a short period only.

Equipment in this category ensures the requisite level of protection during normal operation.

C: Requirements concerning Ingress Protection Rating (IP) as per ATEX harmonized standard IEC 61241-1 Paragraph 6

Dust-tight enclosures IP6X shall be applied for use in:

– zone 20;

– zone 21;

– zone 22 with conductive dust.


Dust-protected enclosures IP5X shall be applied for use in:

– zone 22 with non-conductive dust.



SELECTION CRITERIA FOR VACUUM CLEANERS

Hazardous areas

The following categories of equipment must be used in the Zones indicated:

- Category 1 vacuum cleaners
- Category 1 or 2 vacuum cleaners
- Category 1, 2 and/or 3 vacuum cleaners
in Zone 0 or 20
in Zone 1 or 21
in Zone 2 or 22

Applications

An electrically or pneumatically (air) operated vacuum cleaner, certified ATEX Category 2 by a notified independent testing laboratory must be used to recover the following:

Dry Recovery

  • flour
  • grain
  • corn
  • sawdust
  • sugar
  • fine powders
  • metal dusts
  • coke dusts
  • conductive metal powders
  • conductive non-metallic powders
  • pyrotechnic and anode powders

Liquid Recovery

  • Fuel
  • Petroleum
  • Benzene
  • Butane
  • Propane
  • Alcohol
  • Acetone
  • Lacquer
  • Solvents
  • Liquid Natural Gas
  • Corrosive liquids
  • Acids


Tool Kits

Accessories Kit no 1 for oven cleaning ø 40mm Part no 381479
oven_toolkit_1 Code#Description
1381475-HTSuction Hose Assembly, Metallic & Ceramic. 3m with 50mm hose cuff
2381478Straight Wand with full protective sleeve. 1m
3381478AStraight Wand with half protective sleeve. 1m
4381478MStraight Wand without protective sleeve. 1m
5381491Oven Flat Tool with Teflon blades
Accessories Kit no 2 for oven cleaning ø 40mm Part no 381479A
oven_toolkit_2 Code#Description
1381475-HTSuction Hose Assembly, Metallic & Ceramic. 3m with 50mm hose cuff
2381478Straight Wand with full protective sleeve. 1m
3381478AStraight Wand with half protective sleeve. 1m
4381478MStraight Wand without protective sleeve. 1m
5381491Oven Flat Tool with Teflon blades
6212359Main Filter Assembly, High Temperature, with gasket
7213186BCage for High Temperature Cloth Filter

Spécifications

SPECIFICATIONS
Model Dry only
NON-ATEX
TV-27
ATEX CAT. 3 ZONE 22
ATEX-22E
ATEX CAT. 2 ZONE 21
EXP1-20L DT
Phases / Volts (50Hz) 1 / 240 1 / 240 1 / 240
Power 1050 W 1050 W 1100 W
Motor By-Pass By-Pass Totally-enclosed
fan cooled motor
IP Protection 20 6X 65
Airflow 191 m3/h 173 m3/h 209 m3/h
Vacuum at sealed air intake 1 940 mm H2O 2100 mm H2O 1554 mm H2O
Noise Level 60 dB(A) 75 dB(A) 75 dB(A)
Dimensions (mm) 410 X 410 X 760 530 X 530 X 950 570 X 635 X 1120
Weight 10,2 kg 23,6 kg 40,9 kg

 

You are here: